Introduction Hospital Decontamination Part 1 Sterile Services

Introduction Hospital Decontamination

A decontamination unit often referred to as Sterile Services or CSSD, is responsible for ensuring reusable medical devices. These include surgical instruments, endoscopes, drill systems and other medical equipment. The equipment is decontaminated, inspected, packaged and sterilised before being returned sterile for use in the Operating Theatres or other areas. A strict pattern of work is followed to prevent the risk of infection being transferred to decontamination technicians or patients.

Introduction Hospital Decontamination

Used Surgical instruments are returned for re-processing as soon as possible to the decontamination facility to help prevent body fluids from drying. If blood and other bodily fluids are allowed to dry it will be more challenging to remove proteins, especially on complex devices or cannulated items. Some types of medical devices will require dismantling to ensure the cleaning disinfection process is thorough.

Prior to any pre-cleaning or loading into a washer, disinfector surgical instruments are checked against a tray specification or instrument checklist. This is to ensure all items are present and are not left in the Operating Theatres. The responsible theatre person must always check the instrument tray contents pre and post-surgery. This is to ensure no devices are inadvertently left inside a patient before sending trays for re-processing.

Instruments are then carefully placed into a washer disinfector compliant with HTM01-01 Part D and BS EN 15883:2009. Here they are subjected to a pre-clean wash, detergent wash, thermal disinfection stage. A final reverse osmosis rinse ensures all chemical residuals are removed, followed by a final drying stage. Today washer disinfectors have double door access allowing the now decontaminated instruments to be unloaded in a clean area known as the IAP room (Inspection and Packing).

Controlled Environment

The IAP room is a controlled environment. The air pressure is higher than other area and the air changes via special filters referred to as HEPPA filters. The air standard quality for a sterile services IAP room should reach the minimum ISO Class 8.

Instrument trays are then thoroughly checked for cleanliness. The technicians are trained to undertake function testing ensuring the medical devices are complete, compatible, not broken etc. before placing into their tray. Once checked, the tray is either wrapped in suitable disposable instrument tray wraps or placed into sterilisation containers prior to the last stage.

To enable surgical instruments to be safely used again they must be sterilised. This will ensure the theoretical probability of there being a viable micro-organism present on or in the device. It shall be equal to or less than 1 x 10ˉ⁶.

Packaged trays, packs and single medical devices are then placed into steriliser. This is referred to as a porous load autoclave compliant with HTM01-01 Part C and BS EN 285:2015. Once inside and the chamber sealed, is supplied with steam under pressure. The initial stages of this process are known as negative and positive steam pulses where the air is slowly replaced with steam. The next stage is steam sterilisation where the steam pressure is increased creating a sterilisation temperature between 134ºC – 137ºC  for a minimum of 3 minutes. The final stage includes drawing a vacuum to flash off any residual condensates from the sterilised packages.

Following adequate natural cooling, the sterilised trays are transferred to cooling shelving. They are then distributed to operating theatres, clinics etc. 

All parts of the process adhere to a strict set of standard operating procedures. All decontamination facilities must meet the requirements of ISO 13485:2016 and MDD 93/42/EEC.